06/28/19
Message Overview:
Fault Message:
ACPC SSPC PWR CARD15(A28)/AVION FAN
Fault Code:
2451334ACP
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) Solid-State Power Controller (SSPC) |
| System Description: | 21-54-00 24-50-00 |
| Schematic Diagram: | 21-54-00 [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-54-15 [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The AC Power Center (ACPC) Solid-State Power Controller (SSPC) Power Card has detected a failure with the initialization of the AC SSPCs, the control logic circuitry and/or the load.
Possible Causes:
- AC Power Center (ACPC) (A54)
- Solid-State Power Controller (SSPC) 15
- Avionics Exhaust Fan (B62)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
- If the AVIONICS FAN is inoperative without CAIMS message and breaker is IN, do the troubleshooting related to the AVIONICS FAN FAIL message
- If the breaker is always tripping without CAIMS message, check for a short circuit between the AVIONICS FAN and the SSPC #15
Quick Links:
| Removal of the Avionics Exhaust Fan | AMM 21-54-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Avionics Exhaust Fan | AMM 21-54-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SSPC 15 with SSPC 10 and monitor the R AFT BOOST PUMP.
- If system checks are good, replace SSPC 15 and do close out.
- If fault remains, continue with next step.
- Disconnect the AVIONICS FAN connector B29P1 and remove the SSPC 15 card. Perform continuity check between the connections that follows:
From To Result SSPC 15 P470-25 B29P1-A SSPC 15 P470-28 B29P1-B SSPC 15 P470-31 B29P1-C - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform continuity check between the connections that follows:
From To Result SSPC 15 P470-25 Ground SSPC 15 P470-28 Ground SSPC 15 P470-31 Ground SSPC 15 P470-25 SSPC 15 P470-28 SSPC 15 P470-25 SSPC 15 P470-31 SSPC 15 P470-28 SSPC 15 P470-31 - If there is no continuity, replace AVIONICS FAN and do close out.
- If there is continuity, continue with next step.
- Disconnect connector A54P1 and repeat step 3.
- If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace ACPC.
- Do close out.