Message Overview:
Message Name:
APU BATT FAILED
Message Code:
2451382ACP
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit (APU) |
| System Description: | 24-32-00 |
| Schematic Diagram: | 24-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-32-02 [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] 24-62-15 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
- The Auxiliary Power Unit (APU) Battery Voltage is out of range (V < 22 VDC or V > 35 VDC) for at least 4 seconds.
- The Auxiliary Power Unit (APU) Battery charger detects a failure from the APU battery.
Possible Causes:
- AC Power Center (ACPC) A/D Converter card
- Auxiliary Power Unit (APU) Battery (A89)
- Auxiliary Power Unit (APU) Battery Charger (A90)
- AC Power Center (ACPC) (A54)
- APU Starter-Contactor Assembly (ASCA) (A48)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700T-0083 - Fault Isolation Procedures for AV BATT FAIL & APU BATT FAIL, Caution CAS Messages
- AW700T-0103 - "AV BATT FAIL" & "APU BATT FAIL" CAS Messages Summary
- AW700-24-0252 - "ELEC SYS FAULT" and or "ELEC SYS FAIL" - Nuisance CAS Message during Power Up
Forum Articles/Infoservice/Newsletter:
- Aircraft Short Term Storage: Batteries Disconnection (Forum Aug 2013)
Quick Links:
| Disconnect the APU Battery | AMM 24-32-00-040-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Connect the APU Battery | AMM 24-32-00-440-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Battery Chargers | AMM 24-32-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Battery Chargers | AMM 24-32-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Restoration of the APU Battery | AMM 24-32-09-610-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU Battery | AMM 24-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Battery | AMM 24-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) External AC-to-DC Converter | AMM 24-51-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) External AC-to-DC Converter | AMM 24-51-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU Starter-Contactor Assembly | AMM 24-62-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Starter-Contactor Assembly | AMM 24-62-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Select DC synoptic page. Is the APU battery temperature below -20°C or above 57°C?
- If YES, restore battery to normal operating temperatures and do close out.
- If NO, continue with next step.
- Select DC synoptic page.
- If all the APU BATT parameters are within range, go to step 18.
- Is the APU battery voltage dashed or erroneous? If YES, go to step 8.
- Is the APU battery current dashed or erroneous? If YES, go to step 13.
- Is the APU battery temperature dashed or erroneous? If YES, continue with next step.
- Remove A/D converter card in ACPC. Disconnect APU Battery connectors (A89P1 and A89P2). Perform a continuity check as follows:
From To Result A89P1-M Ground A89P1-a Ground - If there is continuity, continue with next step.
- If there is no continuity, go to step 5.
- Disconnect ACPC connector A54P4. Perform a continuity check as follows:
From To Result A89P1-M Ground A89P1-a Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, go to step 27.
- Perform a continuity check between APU Battery and EMI as follows:
From To Result A89P1-M P520B-20 A89P1-a P520B-21 - If there is no continuity, continue with next step.
- If there is continuity, go to step 7.
- Perform a continuity check between APU Battery and ACPC as follows:
From To Result A89P1-M A54P4-T A89P1-a A54P4-U - If there is continuity, go to step 27.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace A/D converter card in ACPC. Is the fault resolved?
- If YES, do close out.
- If NO, replace APU battery and continue with next step.
- Remove A/D converter card in ACPC. Perform a voltage check as follows:
From To Result P520B-26 Ground - If there is no voltage, continue with next step.
- If there is voltage, replace A/D converter card and do close out.
- Disconnect A48P2 from the ASCA. Perform a continuity check as follows:
From To Result A48P2-a P520B-26 - If there is continuity, go to step 11.
- If there is no continuity, continue with next step.
- Disconnect ACPC connector A54P4. Perform a continuity check as follows:
From To Result A54P4-W A48P2-a - If there is continuity, go to step 27.
- If there is no continuity, repair defective wiring as required and do close out.
- Perform a continuity check as follows:
From To Result P520B-26 Ground - If there is continuity, continue with next step.
- If there is no continuity, replace ASCA and do close out.
- Disconnect ACPC connector A54P4. Perform a continuity check on the ACPC side as follows:
From To Result A48P2-a Ground - If there is continuity, repair defective wiring as required and continue with next step.
- If there is no continuity, go to step 27.
- Remove A/D converter card in ACPC. Disconnect ASCA A48P2. Perform a continuity check as follows:
From To Result A48P2-N P520B-24 A48P2-P P520B-25 - If there is continuity, continue with next step.
- If there is no continuity, go to step 16.
- Perform a continuity check as follows:
From To Result A48P2-N Ground A48P2-P Ground - If there is continuity, continue with next step.
- If there is no continuity, go to step 17.
- Disconnect ACPC A54P4. Perform a continuity check as follows:
From To Result A48P2-N Ground A48P2-P Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, go to step 27.
- Disconnect ACPC A54P4. Perform a continuity check as follows:
From To Result A48P2-N A54P4-f A48P2-P A54P4-g - If there is continuity, go to step 27.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace A/D converter card. Is the fault resolved?
- If YES, do close out.
- If NO, replace ASCA and do close out.
- Interchange APU battery charger with Avionic battery charger. Is the fault resolved?
- YES, replace APU charger and do close out.
- NO, continue with next step.
- Disconnect charger A90P1 and Battery A89P1. Perform a continuity check as follows, using WDM 24-32-02 sheet 1. Make sure pin to pin have continuity and pin to ground is open.
From To Result A89P1-G A90P1-G A89P1-W A90P1-W A89P1-c A90P1-c A89P1-Y A90P1-Y A89P1-K A90P1-K A89P1-H A90P1-H A89P1-X A90P1-X A89P1-J A90P1-J A89P1-G Ground A89P1-W Ground A89P1-c Ground A89P1-Y Ground A89P1-K Ground A89P1-H Ground A89P1-X Ground A89P1-J Ground - If checks are not good, repair defective wiring as required and do close out.
- If checks are good, continue with next step.
- Remove A/D converter card in ACPC. Perform a continuity check as follows:
From To Result A90P1-N P520C-10 - If there is continuity, continue with next step.
- If there is no continuity, go to step 23.
- Perform a continuity check as follows:
From To Result A90P1-N Ground - If there is continuity, continue with next step.
- If there is no continuity, go to step 24.
- Disconnect ACPC A54P4. Perform a continuity check as follows:
From To Result A90P1-N Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, go to step 27.
- Disconnect ACPC A54P4. Perform a continuity check as follows:
From To Result A90P1-N A54P4-M - If there is continuity, go to step 27.
- If there is no continuity, repair defective wiring as required and do close out.
- Send APU battery to battery shop for reconditioning and reinstall it. Is the fault resolved?
- Yes, do close out.
- No, continue with next step.
- Replace A/D converter card. Is the fault resolved?
- Yes, do close out.
- No, continue with next step.
- Replace APU battery.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace ACPC.
- Do close out.