06/28/19
Message Overview:
Fault Message:
APU BATT THERMISTOR B FAILED
Fault Code:
2451383ACP
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit (APU) |
| System Description: | 24-32-00 |
| Schematic Diagram: | 24-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Auxiliary Power Unit (APU) Battery temperature out of range detected by the AC Power Center (ACPC) AC-to-DC Converter Card (A9).
Possible Causes:
- AC Power Center (ACPC) AC-to-DC Converter Card
- Auxiliary Power Unit (APU) Battery (A89)
- AC Power Center (ACPC) (A54)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the APU Battery | AMM 24-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Battery | AMM 24-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) External AC-to-DC Converter |
AMM 24-51-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) External AC-to-DC Converter |
AMM 24-51-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the ACPC A/D converter card (A9) and disconnect APU battery connector A89P1.
- Perform a wiring checks between APU battery and ACPC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace ACPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Refer to drawing APU Batt jumper Install the two jumpers between the pins that follows:
From To A89J1-Y A89P1-M A89J1-K A89P1-a - Make sure the ACPC A/D converter card is installed.
- Select DC synoptic page. Check APU battery temperature.
- If temperature is within normal range, go to step 8.
- If temperature is out of range, continue with new step.
- Replace A/D converter card.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the APU Battery.
- Do close out.