Message Overview:
Fault Message:
ACPC/AC BUS 2 FAILED
Fault Code:
2451386ACP
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) |
| System Description: | 24-50-00 |
| Schematic Diagram: | 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The AC BUS 2 is not powered or reported faulty by the AC Power Center (ACPC).
Possible Causes:
- AC Power Center (ACPC) Contactor (K7)
- AC Power Center (ACPC) (A54)
- Secondary Logic Card (SLC) 2
- Solid-State Power Controller (SSPC) 6 Card
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) LC-Series Contactors (K4, K6, K9, K12) |
AMM 24-51-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) LC-Series Contactors (K4, K6, K9, K12) |
AMM 24-51-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Apply power to the aircraft in the configuration that the ACPC AC bus 2 FAILED message is posted in CAIMS.
- In the flight deck, access AC Synoptic page.
- If AC electrical power is not supplied by VFG 2, go to step 4.
- If AC electrical power is supplied by VFG 2, continue with next step.
- Access ACPC Primary Subassembly. Perform a 115 VAC voltage check as follows:
From To Result K7-A1 Ground K7-B1 Ground K7-C1 Ground - If there is voltage, go to step 5.
- If there is no voltage, troubleshoot involved contactors upstream of K7, leading to VFG 2 output. Replace defective contactors as required and do close out.
- Access ACPC Primary Sub-assembly. Perform a 115 VAC voltage check as follows:
From To Result K7-A3 Ground K7-B3 Ground K7-C3 Ground - If there is voltage, go to step 5.
- If there is no voltage, troubleshoot the involved contactors upstream of K7, leading to the power source. Replace defective contactors as required and do close out.
- Open the circuit breaker to all the loads that are fed by AC BUS 2. Verify if AC BUS 2 is now powered.
- If AC BUS 2 is now powered, push in one circuit breaker at a time to find what circuit or system is shorted.
- If AC BUS 2 is not powered, Continue with next step.
- Remove power from the aircraft. Remove SSPC 6. Verify if the AC BUS 2 is shorted to ground by performing a continuity check as follows:
From To Result CBB7-A2 Ground CBB7-B2 Ground CBB7-C2 Ground - If there is continuity, Troubleshoot the short inside the ACPC, you may have to replace the ACPC and Continue with next step.
- If there is no continuity, Replace contactor K7.
- Is the AC BUS 2 FAILED CAIMS message still present?
- If NO, do close out.
- If YES, continue with next step.
- Swap SSPC card 6 with SSPC card 7.
- If fault follows, replace the SSPC card 6 and do close out.
- If fault remains, continue with next step.
- Swap SLC 2 with SLC 1.
- If fault follows, replace SLC 2 and do close out.
- If fault remains, continue with next step.
- Remove SSPC card 6. Perform a continuity check as follows:
From To Result P220-2 K7-A2 P220-5 K7-B2 P220-8 K7-C2 - If there is continuity, continue with next step.
- If there is no continuity, go to step 14.
- Remove SLC 2 and Perform a continuity check as follows:
From To Result P220A-20 P210B-13 P220B-20 P210C-13 P220C-20 P210C-14 - If there is continuity, continue with next step.
- If there is no continuity, go to step 14.
- Perform a continuity check as follows:
From To Result P220A-20 Ground P220B-20 Ground P220C-20 Ground - If there is continuity, go to step 14.
- If there is no continuity, continue with next step.
- Inspect contacts for SLC 2 and SSPC 6 and make sure the cards are properly seated when re-installed.
- Replace ACPC.
- Do close out.