background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

ACPC/AC BUS 1 FAILED

FaultS Code:

2451395ACP

Associated CAS:

ELEC SYS FAIL
(Caution)

Reporting LRU: AC Power Center (ACPC)
System Description: 24-50-00
Schematic Diagram: 24-51-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The AC BUS 1 is not powered or reported faulty by the AC Power Center (ACPC).

Possible Causes:

  • AC Power Center (ACPC) (A54)
  • AC Power Center (ACPC) Contactor (K5)
  • AC Power Center (ACPC) Secondary Logic Card (SLC) 1
  • AC Power Center (ACPC) Solid State Power Controller (SSPC) Card 5
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC)L-Series Contactors AMM 24-51-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC)L-Series Contactors AMM 24-51-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC)LC-Series Contactors (K4, K6, K9, K12) AMM 24-51-37-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC)LC-Series Contactors (K4, K6, K9, K12) AMM 24-51-37-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC)Solid-State Power Controller AMM 24-51-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC)Solid-State Power Controller AMM 24-51-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Apply power to the aircraft in the configuration that the ACPC BUS 1 FAILED message is posted in CAIMS.
  2. In the flight deck, access AC Synoptic page.

    1. If AC electrical power is not supplied by VFG 1, go to step 4.
    2. If AC electrical power is supplied by VFG 1, continue with next step.

  3. Access ACPC Primary Sub-assembly and perform a 115 VAC voltage check as follows:

    From To Result
    K5-A1 Ground
    K5-B1 Ground
    K5-C1 Ground

    1. If there is voltage, go to step 5.
    2. If there is no voltage, troubleshoot the involved contactors upstream of K5, leading to VFG 1 output. Replace defective contactors as required and do close out.

  4. Access ACPC Primary Sub-assembly and perform a 115 VAC as follows:

    From To Result
    K5-A3 Ground
    K5-B3 Ground
    K5-C3 Ground

    1. If there is no voltage, troubleshoot the involved contactors upstream of K5, leading to the power source and do close out.
    2. If there is voltage, continue with next step.

  5. Open the circuit breaker to all the loads that are fed by AC BUS 1. Verify if AC BUS 1 is now powered.

    1. If AC BUS 1 is now powered, push in one circuit breaker at a time to find what circuit or system is shorted.
    2. If AC BUS 1 is not powered, continue with next step.

  6. Remove power from the aircraft and remove SSPC 5. Verify if the AC BUS 1 is shorted to ground by performing a continuity check as follows:

    From To Result
    K5-A2 Ground
    K5-B2 Ground
    K5-C2 Ground

    1. If there is no continuity, replace contactor K5 and do close out.
    2. If there is continuity, troubleshoot the short inside the ACPC, you may have to replace the ACPC and continue with next step.

  7. Is the AC BUS 1 FAILED CAIMS message still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  8. Swap SSPC card 5 with SSPC card 4.

    1. If system checks are good, replace SSPC card 5 and do close out.
    2. If fault remains, continue with next step.

  9. Swap SLC 1 with SLC 2, 3 or 4.

    1. If system checks are good, replace SLC 1 and do close out.
    2. If fault remains, continue with next step.

  10. Remove SSPC card 5 and perform a continuity check as follows:

    From To Result
    P160-2 K3-A3
    P160-5 K3-B3
    P160-8 K3-C3

    1. If there is no continuity, go to step 14.
    2. If there is continuity, continue with next step.

  11. Remove SLC 1 and perform a continuity check as follows:

    From To Result
    P160A-20 P110B-13
    P160B-20 P110C-13
    P160C-20 P110C-14

    1. If there is no continuity, go to step 14.
    2. If there is continuity, continue with next step.

  12. Perform a continuity check as follows:

    From To Result
    P160A-20 Ground
    P160B-20 Ground
    P160C-20 Ground

    1. If there is continuity, go to step 14.
    2. If there is no continuity, continue with next step.

  13. Inspect contacts for SLC 1 and SSPC 5 and make sure the cards are properly seated when re-installed.
  14. Replace ACPC.
  15. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.