Message Overview:
Fault Message:
ACPC PRIMARY LOGIC CARD #3-A21/GCU1
Fault Code:
2453003ACP
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) |
| System Description: | 24-23-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
AC Power Center (ACPC) Primary Logic Card (PLC) 3 has detected an RS422 transmission failure with Generator Control Unit (GCU) 1 during loop back test. Even though it can no longer communicate with the ACPC through the RS422 bus, the GCU remains operational.
Possible Causes:
- Generator Control Unit (GCU) 1 (A56)
- AC Power Center (ACPC) (A54)
- AC Power Center (ACPC) Primary Logic Card (PLC) 3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 1 with GCU 2, 3, 4 or APU GCU. Is the fault resolved?
- If YES, replace GCU 1 and do close out.
- If NO, continue with next step.
- Access ACPC logic assembly. Swap PLC 3 with PLC 1. Is the fault still present?
- If NO, replace PLC 3 and do close out.
- If YES, continue with next step.
- Disconnect GCU 1 connector A56P2. Remove PLC 3. Perform a continuity check as follows:
From To Result A56P2-9 Ground A56P2-15 Ground - If there is continuity, go to step 5.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A56P2-9 P415B-44 A56P2-15 P415B-45 - If there is continuity, replace PLC 3 and do close out.
- If there is no continuity, go to step 6.
- Disconnect ACPC connector A54P6. Perform a continuity check as follows:
From To Result A56P2-9 Ground A56P2-15 Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, go to step 7.
- Disconnect ACPC connector A54P6. Perform a continuity check as follows:
From To Result A56P2-9 A54P6-a A56P2-15 A54P6-b - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace ACPC.
- Do close out.