Message Overview:
Fault Message:
DCPC DIODE #7-D7 FAILED
Fault Code:
2460452DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
DC Power Center (DCPC) does not sense the voltage from the Diode D7.
Possible Causes:
- DC Power Center (DCPC) Diode (D7)
- Electronic Module (EM) 5
- DC 1 Feeder Card
- Cabin Feeder Card
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Cabin DC Feeder | AMM 24-61-41-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Cabin DC Feeder | AMM 24-61-41-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Diodes (D6 and D7) | AMM 24-61-49-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Diodes (D6 and D7) | AMM 24-61-49-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| DC Power Center (DCPC) Assembly | CMM 24-61-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if DCPC DIODE #6-D6 FAILED fault also exists.
- If YES, replace the Cabin feeder card and do close out.
- If NO, continue with next step.
- Swap the DC 1 feeder card with DC 2 feeder card. Does the fault follow the card?
- If YES, replace DC 1 feeder card and do close out.
- If NO, continue with next step.
- Remove DC 1 Feeder card and cabin feeder card in DCPC. Disconnect EM5 connector P502. Perform a resistance check for a short circuit as follows:
From To Result P502-5 P502-7 - If there is a short circuit, replace D7 and do close out.
- If there is no short circuit, continue with next step.
- Perform a continuity check as follows:
From To Result P502-6 Ground P502-8 Ground - If there is continuity, go to step 10.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P502-6 P131A-11 P502-8 P531A-11 - If there is continuity, continue with next step.
- If there is no continuity, go to step 10.
- Perform a resistance check on EM5 as follows:
From To Value Result J502-4 J502-5 562 Ω J502-5 J502-6 24 KΩ J502-7 J502-8 10 KΩ - If the resistance values are incorrect, replace EM5 and do close out.
- If the resistance values are correct, continue with next step.
- Perform a continuity check as follows:
From To Result P502-5 D7-Anode - If there is no continuity, go to step 10.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From TO Result P502-7 D7-Cathode - If there is no continuity, go to step 10.
- If there is continuity, continue with next step.
- Replace Diode D7. Is the fault resolved?
- If YES, do close out.
- If NO, continue with next step.
- Replace DCPC.
- Do close out.