Message Overview:
Fault Message:
ESS TRU 2 FAILED/WRG/ESS TRU 2 FEED
Fault Code:
2460473DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
DC Power Center (DCPC) has detected a Essential Transformer Rectifier Unit (ESS TRU) 2 failure.
Possible Causes:
- Essential Transformer Rectifier Unit (ESS TRU) 2 (A76)
- DC Power Center (DCPC) DC Power Quality Monitor (DCPQM) Card 2
- Alternate DC Power Distribution (ADCPD) 2
- DC Power Center (DCPC) Electronic Module (EM4)
- DC Power Center (DCPC) Primary Logic Cards
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
If the TRU voltage indication on the DC synoptic page is less than 26 volts, suspect a bad or a missing input phase from the AC system (ACPC).
Quick Links:
| Removal of the Transformer Rectifier Units | AMM 24-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Transformer Rectifier Units | AMM 24-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Alternate DC-Power Distribution (ADCPD) Panels No. 1 and No. 2 | AMM 24-65-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Alternate DC-Power Distribution (ADCPD) Panels No. 1 and No. 2 | AMM 24-65-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap ESS TRU 2 with TRU 2.
- If system checks are good, replace ESS TRU 2 and do close out.
- If fault remains, continue with next step.
- Check for 115 VAC of TRU voltage input phases.
- If voltage are good, go to step 4.
- If one or more of the phases are less than 115 VAC, continue with next step.
- Troubleshoot the power input from the ACPC (AC BUS 4).
- If system checks are good, do close out. Repair as required.
- If fault remains, continue with next step.
- Check for 24 VDC at the DCPC input (stud T14) with load on the system.
NOTE: Use an oscilloscope to take the measurement in order to make sure there is no fluctuation of the DC signal.- If voltage are good, go to step 6.
- If one or more of the phases are less than 24 VDC, continue with next step.
- Perform wiring checks between DCPC and the ESS TRU including the ADCPD 2.
- If wiring checks are good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Swap DCPQM card 2 and the DCPQM card 1 in DCPC.
- If system checks are good, replace DCPQM card 2 and do close out.
- If fault remains, continue with next step.
- In the DCPC, remove the three Primary Logic Cards, the DCPQM card 2 and disconnect connector P407 of Electronic Module 4.
- Perform an EMI filter check by performing a continuity check as follows:
From To Result P407-8 Ground P407-10 Ground - If there is continuity, go to step 11.
- If there is no continuity, continue with next step.
- Check the resistances of the Electronic Module 1 as follows:
From To Expected Result Result J407-8 J407-9 2 KOhms J407-9 J407-10 1.5 KOhms - If resistance is within range, go to step 11.
- If resistance is out of range, continue with next step.
- Replace EM 4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace DCPC.
- Do close out.