03/12/21
Message Overview:
Message Name:
AV BATT THERMISTOR B FAILED
Message Code:
2460482DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-32-00 |
| Schematic Diagram: | 24-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Avionics Battery temperature out of range detected by the DC Power Center (DCPC) DC Power Quality Monitor (DCPQM) Card 2.
Possible Causes:
- Avionics Battery (AV BATT) (A182)
- DC Power Quality Monitor (DCPQM) Card 2
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Avionics Battery | AMM 24-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Avionics Battery | AMM 24-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap DCPQM 2 with DCPQM 1. (select DC synoptic page to monitor AV battery temperature)
- If system checks are good, replace DCPQM 2 and do close out.
- If fault remains, continue with next step.
- Remove the DCPQM 2 and disconnect avionic battery connector A182P1. Perform a continuity check as follows:
From To Result A182P1-M Ground A182P1-a Ground - If there is continuity, go to step 4.
- If there is no continuity, continue with next step.
- Replace avionic battery.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Disconnect DCPC connector A63P2. Perform continuity check as follows:
From To Result A63P2-R Ground A63P2-g Ground - If there is no continuity, go to step 6.
- If there is continuity, continue with next step.
- Perform continuity check between avionics battery and DCPC as follows:
From To Result A182P1-M A63P2-R A182P1-a A63P2-g - If there is continuity, continue with next step.
- If there is no continuity, repair the defective wiring as required and do close out.
- Replace the DCPC.
- Do close out.