Message Overview:
Fault Message:
ASCA FAILED-DCPC (LEVEL C)
Fault Code:
2460485DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-40-00 |
| Schematic Diagram: | 24-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The DC Power Center Battery/Ram-Air-Turbine Interface (DCPC BAT RAT I/F) Card detects a discrepancy between the External Power Contactor (EPC) status and the External Power Monitor (EPM) status.
Possible Causes:
- Auxiliary Power Unit (APU) Starter-Contactor Assembly (ASCA) (A48)
- Battery/Ram-Air-Turbine Interface (BAT RAT I/F) Card
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Battery/Ram-Air-Turbine Interface Unit | AMM 24-61-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Battery/Ram-Air-Turbine Interface Unit | AMM 24-61-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU Starter-Contactor Assembly | AMM 24-62-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Starter-Contactor Assembly | AMM 24-62-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| DC Power Center (DCPC) Assembly | CMM 24-61-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Get access to the Signboard menu and compare DCPC IN and ACPC IN labels that follow: (Only bits in gray need to be look at)
For DCPC IN label 025
For ACPC IN label 046- If bits EPC and EPM are the same between two labels, go to step 12.
- If bits EPC and EPM are different between two labels, continue with next step.
- Get access to the APU Battery and disconnect connector A89P2.
- Get access to the ASCA and disconnect connector A48P2.
- Perform continuity checks between ASCA and ground as follow:
From To Result A48P2-c Ground - If there is continuity, go to step 12.
- If there is no continuity, continue with next step.
- Remove the DCPC BAT RAT I/F card.
- Perform a wiring checks as follow:
From To Result A48P2-c P410C-13 A48P2-b P410C-11 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform continuity checks between ASCA and ground as follow:
From To Result A48P2-c Ground A48P2-b Ground - If there is continuity, go to step 9.
- If there is no continuity, continue with next step.
- Replace DCPC BAT RAT I/F Card.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Disconnect DCPC connector A63P1.
- Perform continuity checks as follow:
From To Result P410C-11 Ground P410C-13 Ground - If there is no continuity, go to step 12.
- If there is continuity, continue with next step.
- Replace DCPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace ASCA.
- Do close out.