Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

RATLC FAILED -K3

Fault Code:

2460492DCP

Associated CAS:

ELEC SYS FAIL
(Caution)

RAT GEN FAIL
(Caution)

Reporting LRU: Ram-Air-Turbine Line Contactor (RATLC)
System Description: 24-50-00
Schematic Diagram: 24-23-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-23-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Fault message will be posted if the Ram-Air-Turbine (RAT) Line Contactor (RATLC) status is not in the expected configuration during the various phases of the Initiated RAT TEST or continuous monitoring.

Possible Causes:

  • Cockpit Circuit Breaker Panel (CCBP) (A35)
  • Ram Air Turbine (RAT) Line Contactor (RATLC) (K3)
  • Battery/Ram-Air-Turbine Interface (BAT RAT I/F) Card
  • DC Power Center (DCPC) (A63)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Cockpit Circuit-Breaker Panel (CCBP)H-Series Contactors AMM 24-52-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Cockpit Circuit-Breaker Panel (CCBP)H-Series Contactors AMM 24-52-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) AMM 24-61-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) AMM 24-61-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC)Battery/Ram-Air-Turbine Interface Unit AMM 24-61-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC)Battery/Ram-Air-Turbine Interface Unit AMM 24-61-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Make sure the RAT is not deployed. Remove power from the A/C. Disconnect DCPC connector A63P2. Perform a continuity check as follows:

    From To Result
    A63P2-J Ground

    1. If there is no continuity, go to step 4.
    2. If there is continuity, continue with next step.

  2. Access the CCBP K3. Disconnect RATLC K3 contact 12. Perform a continuity check as follows:

    From To Result
    A63P2-J Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  3. Replace RATLC K3. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  4. Disconnect DCPC connector A63P2. Remove BATT/RAT interface card. Perform a continuity check as follows:

    From To Result
    A63J2-J Ground

    1. If there is continuity, go to step 11.
    2. If there is no continuity, continue with next step.

  5. Perform a continuity check as follows:

    From To Result
    A63J2-J P410A-11

    1. If there is no continuity, go to step 11.
    2. If there is continuity, continue with next step.

  6. Perform a continuity check as follows:

    From To Result
    K3-12 A63P2-J

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  7. Disconnect RAT GCU connector A191P1. Perform a continuity check as follows:

    From To Result
    A191P1-b Ground
    A191P1-D Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  8. Perform a continuity check as follows:

    From To Result
    A191P1-b K3-X1
    A191P1-D K3-X2

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  9. Replace BATT/RAT interface card. Is the fault resolved?

    1. If YES, do close out.
    2. If NO, continue with next step.

  10. Replace RATLC K3.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  11. Replace DCPC.
  12. Do close out.