06/28/19
Message Overview:
Fault Message:
FUSE F4-ELECTRONIC MODULE #3 FAILED
Fault Code:
2460498DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
DC Power Center (DCPC) has detected a defective Electrical Module 3 (EM3) Fuse F4.
Possible Causes:
- Electronic Module (EM) 3
- DC Power Center (DCPC) Right Microprocessor Card
- DC ESS Feeder Card
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Fault-Tolerant Microprocessor | AMM 24-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Fault-Tolerant Microprocessor | AMM 24-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the DC ESS Feeder Card and the Right Microprocessor from the DCPC.
- Disconnect connector P305 of EM 3.
- Perform a continuity check as follows:
From To Result J305-15 J305-16 - If there is no continuity, go to step 8.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P305-16 Ground P305-17 Ground - If there is continuity, go to step 9.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P305-16 P331A-9 P305-17 P3C-48 - If there is no continuity, go to step 9.
- If there is continuity, continue with next step.
- Swap the DC ESS Feeder card with the DC 1 Feeder Card. Does the fault transfer over to EM 1?
- If YES, replace DC ESS Feeder Card and do close out.
- If NO, continue with next step.
- Swap the Right Microprocessor with the Left Microprocessor. Is the fault resolved?
- If YES, replace Right Microprocessor and do close out.
- If NO, continue with next step.
- Replace EM3.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace DCPC.
- Do close out.