06/28/19
Message Overview:
Fault Message:
FUSE F5-ELECTRONIC MODULE #2 FAILED
Fault Code:
2460499DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
DC Power Center (DCPC) has detected a defective Electrical Module 2 (EM2) Fuse F5.
Possible Causes:
- Electronic Module (EM2)
- DC Power Center (DCPC) Left Microprocessor Card
- DC Power Center (DCPC) Right Microprocessor Card
- DC Power Center (DCPC) Battery/Ram-Air-Turbine Interface Unit
- DC 2 Feeder Card
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Fault-Tolerant Microprocessor | AMM 24-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Fault-Tolerant Microprocessor | AMM 24-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Battery/Ram-Air-Turbine Interface Unit | AMM 24-61-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Battery/Ram-Air-Turbine Interface Unit | AMM 24-61-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)Secondary-Power Distribution Assembly (SPDA) Feeder | AMM 24-61-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the DC 2 Feeder Card, Battery/RAT I/F Card, Left Microprocessor and the Right Microprocessor from the DCPC.
- Disconnect connector P205 of EM 2.
- Perform a continuity check as follows:
From To Result J205-12 J205-13 - If there is no continuity, go to step 11.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P205-13 Ground P205-14 Ground - If there is continuity, go to step 12.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P205-13 P231A-8 - If there is no continuity, go to step 12.
- If there is continuity, continue with next step.
- Set your Multimeter on Diode Testing Mode and perform a continuity check as follows:
From To Result P205-14 P2C-46 P205-14 P3C-46 P205-14 P410C-46 - If there is no continuity, go to step 12.
- If there is continuity, continue with next step.
- Swap DC 2 Feeder card with DC 1 Feeder card. Does the fault transfer over to EM 1?
- If YES, replace DC 2 Feeder card and do close out.
- If NO, continue with next step.
- Replace the Right Microprocessor. Is the fault resolved?
- If YES, do close out.
- If NO, reinstall the original right Microprocessor and continue with next step.
- Replace the Left Microprocessor. Is the fault resolved?
- If YES, do close out.
- If NO, reinstall the original left Microprocessor and continue with next step.
- Replace BATT/RAT I/F card. Is the fault resolved?
- If YES, do close out.
- If NO, continue with next step.
- Replace EM 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace DCPC.
- Do close out.