Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

FUSE F7-ELECTRONIC MODULE #4 FAILED

Fault Code:

2460501DCP

Associated CAS:

ELEC SYS FAULT
(Advisory)

Reporting LRU: DC Power Center (DCPC)
System Description: 24-60-00
Schematic Diagram: 24-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

DC Power Center (DCPC) has detected a defective Electrical Module 4 (EM4) Fuse F7.

Possible Causes:

  • Electronic Module (EM4)
  • DC Power Center (DCPC) Right Microprocessor Card
  • DC Power Center (DCPC Battery/Ram-Air-Turbine Interface Unit
  • BATT Feeder Card
  • DC Power Center (DCPC) (A63)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the DC Power Center (DCPC) AMM 24-61-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) AMM 24-61-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Fault-Tolerant Microprocessor AMM 24-61-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Fault-Tolerant Microprocessor AMM 24-61-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Battery/Ram-Air-Turbine Interface Unit AMM 24-61-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Battery/Ram-Air-Turbine Interface Unit AMM 24-61-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder AMM 24-61-37-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder AMM 24-61-37-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Electronic Modules AMM 24-61-65-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Electronic Modules AMM 24-61-65-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove the BATT Feeder Card, Battery/RAT I/F Card and the Right Microprocessor from the DCPC.
  2. Disconnect connector P407 of EM 4.
  3. Perform a continuity check as follows:

    From To Result
    J407-15 J407-16

    1. If there is no continuity, go to step 9.
    2. If there is continuity, continue with next step.

  4. Perform a continuity check as follows:

    From To Result
    P407-16 Ground
    P407-17 Ground

    1. If there is continuity, go to step 10.
    2. If there is no continuity, continue with next step.

  5. Perform a continuity check as follows:

    From To Result
    P407-16 P431A-9
    P407-17 P3C-50
    P407-17 P410C-50

    1. If there is no continuity, go to step 10.
    2. If there is continuity, continue with next step.

  6. Swap the BATT Feeder card with DC 1 Feeder Card. Does the fault transfer over to EM 1?

    1. If YES, replace BATT Feeder card and do close out.
    2. If NO, continue with next step.

  7. Swap the Right Microprocessor with the Left Microprocessor. Is the fault resolved?

    1. If YES, replace Right Microprocessor and do close out.
    2. If NO, continue with next step.

  8. Replace BATT/RAT I/F card. Is the fault resolved?

    1. If YES, do close out.
    2. If NO, continue with next step.

  9. Replace EM 4.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  10. Replace DCPC.
  11. Do close out.