06/28/19
Message Overview:
Fault Message:
CDU 1/SPDA 1 / WRG
Fault Code:
2462601SPD
Associated CAS:
| Reporting LRU: | Electrical Management System Control-and-Display Unit (EMS CDU) 1 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] 24-70-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
ARINC 429 communication between the Secondary-Power Distribution Assembly (SPDA) 1 and the Electrical Management System Control-and-Display Unit (EMS CDU) is faulty. The Line Replacement Unit (LRU) transmits a test label on a periodic basis and the label is echoed back by the receiving LRU.
Possible Causes:
- Electrical Management System Control-and-Display Unit (EMS CDU) 1 (A94)
- Secondary-Power Distribution Assembly (SPDA) 1 (A13)
- PCB3/Junction Box (JB3)
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum/Info-service/Newsletter: None
- Make sure the Junction Box #3 is racked properly. Field experience revealed many cases of Junctions Boxes not installed properly.
- Flight deck effect:
- On the EMS CDU 1, SPDA 1 electrical loads are dashed
- Alternative fault confirmation:
- On EMS CDU 1, select Diagnostic mode
- Select SYSTEM - CNTL key (page 1/3)
- Select lower left side key
- Select lower right side key
- On EMS CDU 1, select Diagnostic mode
Quick Links:
| Removal of the Junction Box JB3 | AMM 24-00-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 | AMM 24-00-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB3 Circuit-Cards | AMM 24-00-02-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 Circuit-Cards | AMM 24-00-02-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Electrical Management System Control-and-Display Units (EMS CDU) |
AMM 24-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Electrical Management System Control-and-Display Units (EMS CDU) |
AMM 24-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap EMS CDU 1 with EMS CDU 2.
- If system checks are good, replace EMS CDU 1 and do close out.
- If fault remains, continue with next step.
- Swap SPDA 1 with SPDA 3.
- If system checks are good, replace SPDA 1 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between EMS CDU 1, SPDA 1, DCPC, SPDA 4 and JB3.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace DCPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PCB3/Junction Box JB3.
- Do close out.