background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/01/19

Message Overview:

Fault Message:

SPDA 1 FAILED (LEVEL C)-CARD #6

Fault Code:

2463101SPD

Associated CAS:

ELEC SYS FAULT
(Advisory)

Reporting LRU: Secondary Power Distribution Assembly (SPDA) 1
System Description: 24-60-00
Schematic Diagram: 24-62-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-62-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Secondary Power Distribution Assembly (SPDA) 1 has detected an internal failure related to DC Power Module Card 6.

  1. DC Power Module Card failure:

    1. Solid State Power Controller (SSPC) setting does not match the specified programming code.
    2. SSPC status does not agree with its commanded state.

Possible Causes:

  • Secondary Power Distribution Assembly (SPDA) 1 (A13)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Secondary-Power Distribution Assemblies AMM 24-62-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Secondary-Power Distribution Assemblies AMM 24-62-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Cycle the aircraft power.
  2. Swap SPDA 1 with SPDA 2. Is the fault still present?

    1. If NO, replace SPDA 1 and do close out.
    2. If YES, continue with next step.

  3. Perform the troubleshooting of the loads (associated systems) connected to card 6. Refer to the document below:
    SPDA 1 CARD 6 ASSOCIATED SYSTEM

    SPDA Card Load Circuit Breaker Name
    6 1 FMS CDU2
    2 RMU 2 PWR A
    3 R NOSE LDG LT
    4 GALLEY FAN
    5 AILERON TRIM
    6 SPARE 425
    7 CKPT TEMP SENSOR
    8 CVR ERASE
    9 SPARE 123
    10 FLOOR/EYE LTS

  4. Do close out.