07/01/19
Message Overview:
Fault Message:
SPDA 1 FAILED(LEVEL C)-L MICROPROC
Fault Code:
2463104SPD
Associated CAS:
| Reporting LRU: | Secondary Power Distribution Assembly (SPDA) 1 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Secondary Power Distribution Assembly (SPDA) 1 detects a failure with the Left Microprocessor.
Possible Causes:
- Secondary Power Distribution Assembly (SPDA) 1 (A13)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Replace SPDA 1.
- Do close out.