07/01/19
Message Overview:
Fault Message:
SPDA 2 FAILED (LEVEL C)-CARD#4
Fault Code:
2463201SPD
Associated CAS:
| Reporting LRU: | Secondary Power Distribution Assembly (SPDA) 2 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Secondary Power Distribution Assembly (SPDA) 2 has detected an internal failure related to DC Power Module Card 4.
- DC Power Module Card failure:
- Solid-State Power Controller (SSPC) setting does not match the specified programming code.
- SSPC status does not agree with its commended state.
Possible Causes:
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Cycle the aircraft power.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SPDA 2 with SPDA 1.
- If system checks are good, replace SPDA 2 and do close out.
- If fault remains, continue with next step.
- Perform the troubleshooting of the associated systems. Refer to the table below:SPDA 2 CARD 4 ASSOCIATED SYSTEM
SPDA card Load Circuit Breaker Name 4 1 P FEEL/RUD LIM 1 2 L PACK CTLR CH A 3 AIRPHONE REPEATER 4 AP 1 SERVOS 5 ADF 1 6 SPARE 535 7 CAB TEMP SENSOR 8 AFT TANK L SOV O 9 AFT TANK L SOV C 10 BUILD 4.0: SPARE 531POST BUILD 4.0: WING TIP LTS - Do close out.