07/01/19
Message Overview:
Fault Message:
SPDA 2 FAILED (LEVEL C)-CARD#6
Fault Code:
2463205SPD
Associated CAS:
| Reporting LRU: | Secondary Power Distribution Assembly (SPDA) 2 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Secondary Power Distribution Assembly (SPDA) 2 has detected an internal failure related to DC Power Module Card 6.
- DC power module card failure:
- Solid-State Power Controller (SSPC) setting does not match the specified programming code.
- SSPC status does not agree with its commended state.
Possible Causes:
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Cycle the aircraft power.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SPDA 2 with SPDA 1.
- If system checks are good, replace SPDA 2 and do close out.
- If fault remains, continue with next step.
- Perform the troubleshooting of the associated systems. Refer to the document below:
SPDA card Load Circuit Breaker Name 6 1 L PACK CTLR CH B 2 IRS 2 PWR A 3 HF 1 TRANSCVR 4 DC 2 CABIN FEED 2 5 BUILD 4.0: OIL TANK PROBEBUILD 4.0NP: OIL TANK PROBEPOST BUILD 4.0NP: SPARE 124 6 SPARE 128 7 HUMIDIFIER 8 FDR 9 DME 1 10 VOR/ILS 1 - Do close out.