07/01/19
Message Overview:
Fault Message:
SPDA 3 FAILED (LEVEL C)-CARD#7
Fault Code:
2463305SPD
Associated CAS:
| Reporting LRU: | Secondary Power Distribution Assemblies (SPDA) 3 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Secondary Power Distribution Assemblies (SPDA) 3 has detected an internal failure related to DC power module card 7.
- DC power module card failure:
- SSPC setting does not match the specified programming code.
- SSPC status does not agree with its commanded state.
Possible Causes:
- Secondary Power Distribution Assemblies (SPDA) 3 (A15)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Cycle the aircraft power.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SPDA 3 with SPDA 4.
- If system checks are good, replace SPDA 3 and do close out.
- If fault remains, continue with next step.
- Perform the troubleshooting of the associated systems. Refer to the document below:
SPDA card Load Circuit Breaker Name 7 1 SLAT/FLAP CTLR 2 2 IRS 3 PWR B 3 FUEL COMPUTR CH B 4 IRS 2 PWR B 5 AUTO PRESS 1 6 R ENG BLEED VLV 7 R BMC SENSORS 8 R ENG HP VLV 9 PRE BUILD 6.0: SPARE 357
POST BUILD 6.0: EVS HEAT CTL10 SPARE 352 - Do close out.