07/01/19
Message Overview:
Fault Message:
SPDA 3 FAILED (LEVEL C)-CARD#8
Fault Code:
2463306SPD
Associated CAS:
| Reporting LRU: | Secondary Power Distribution Assemblies (SPDA) 3 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Secondary Power Distribution Assemblies (SPDA) 3 has detected an internal failure related to DC Power Module Card 8.
- DC Power Module Card failure:
- SSPC setting does not match the specified programming code.
- SSPC status does not agree with its commanded state.
Possible Causes:
- Secondary Power Distribution Assemblies (SPDA) 3 (A15)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Cycle the aircraft power.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SPDA 3 with SPDA 4.
- If system checks are good, replace SPDA 3 and do close out.
- If fault remains, continue with next step.
- Perform the troubleshooting for the associated systems. Refer to the table below:
SPDA Card Load Circuit Breaker Name 8 1 R PACK CTLR CH A 2 DC 2 CABIN FEED 3 3 BUILD 4.0: L PACK DUCT HEAT
POST BUILD 4.0: OXYGEN LTS4 NAV LTS 5 AFT TANK R SOV O 6 AFT TANK R SOV C 7 GPS 2 8 IRS 2 FAN 9 R BMC CH A 10 RAD ALT 2 - Do close out.