07/01/19
Message Overview:
Fault Message:
SPDA 4 FAILED (LEVEL C)-CARD#2
Fault Code:
2463406SPD
Associated CAS:
| Reporting LRU: | Secondary Power Distribution Assemblies (SPDA) 4 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Secondary Power Distribution Assemblies (SPDA) 4 has detected an internal failure related to DC power module card 2.
- DC power module card failure:
- SSPC setting does not match the specified programming code.
- SSPC status does not agree with its commended state.
Possible Causes:
- Secondary Power Distribution Assemblies (SPDA) 4 (A16)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Cycle the aircraft power.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SPDA 4 with SPDA 3.
- If system checks are good, replace SPDA 4 and do close out.
- If fault remains, continue with next step.
- Perform the troubleshooting of the associated systems. Refer to the table below:
SPDA card Load Circuit Breaker Name 2 1 SPARE 173 2 SATCOM DATA UNIT 3 SATCOM ANT CTLR 4 GEAR CTL A PWR 1 5 BUILD 4.0: SPARE 125
POST BUILD 4.0: MISC COCKPIT LIGHTS6 AUDIO PANEL 3A 7 BUILD 4.0: SPARE 527
POST BUILD 4.0: PULSE LIGHTS8 COPILOT INTG LTS 9 DATALINK 10 SPARE 538 - Do close out.