Message Overview:
Fault Message:
EMS CDU 1 /EMS CDU 2/WRG
Fault Code:
2470205CDU
Associated CAS:
| Reporting LRU: | Electrical Management System Control Display Unit (EMS CDU) |
| System Description: | 24-70-00 |
| Schematic Diagram: | 24-70-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-70-03 [ Global Express ] [ G5000 ] [ Global XRS ] 24-70-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
ARINC 429 communication between the Electrical Management System Control and Display Unit (EMS CDU) 1 and the EMS CDU 2 is faulty. The Line Replacement Unit (LRU) transmits on periodic basis a test label that is turned around by the receiving LRU.
Possible Causes:
- Electrical Management System Control and Display Unit (EMS CDU) 1 (A94)
- Electrical Management System Control and Display Unit (EMS CDU) 2 (A91)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between EMS CDU 1 and EMS CDU 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace defective EMS CDU.
- Do close out.