07/01/19
Message Overview:
Fault Message:
DISCRT WATCHDOG CDU 2B
Fault Code:
2473003CDU
Associated CAS:
| Reporting LRU: | Electrical Management System Control-and-Display Unit (EMS CDU) 2 |
| System Description: | 24-70-00 |
| Schematic Diagram: | 24-70-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-70-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Electrical Management System Control-and-Display Unit (EMS CDU) 2 Channel B is reporting that there is a fault detected internally with the watchdog timer.
Possible Causes:
- Electrical Management System Control-and-Display Unit (EMS CDU) 2 (A91)
- Data Acquisition Unit (DAU) 2 (A18)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Electrical Management System Control-and-Display Units (EMS CDU) |
AMM 24-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Electrical Management System Control-and-Display Units (EMS CDU) |
AMM 24-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform a complete Aircraft power reset. Is the CAIMS fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap DAU 2 with DAU 1. Did the fault follow the DAU?
- If YES, continue with next step.
- If NO, replace DAU 2 and do close out.
- Replace EMS CDU 2.
- Do close out.