06/24/19
Message Overview:
Fault Message:
ADC#1/ADC#2/ADC#3/MACH XDUCER/SPC A
Fault Code:
2730202STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
When one or more of the following occurs:
- Data read by the Stall Protection Computer (SPC) Channel A is not the same as data sent from the air data computers OR,
- The data read from the air data computers and the Mach Transducer do not agree with Stall Protection Computer Channel A
Possible Causes:
- Micro Air Data Computer 1 (ADC) (A27)
- Micro Air Data Computer 2 (ADC) (A28)
- Micro Air Data Computer 3 (ADC) (A29)
- Mach Transducer (MT80)
- Stall Protection Computer (SPC) (A40)
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-27-0363 - No Fault Found initiative: Stall Protection Computer
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Mach Transducer | AMM 27-32-13-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Mach Transducer | AMM 27-32-13-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Micro Air-Data Computers | AMM 34-11-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Micro Air-Data Computers | AMM 34-11-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if there are any ADC related CAS messages posted.
- If there are any ADC related CAS messages posted, troubleshoot them.
- If there are no ADC related CAS messages posted, continue with next step.
- Replace Mach Transducer.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between Mach Transducer, MADCs and SPC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Stall Protection Computer (SPC).
- Do close out.