06/25/19
Message Overview:
Fault Message:
PITCH DISCNNCT LOCK/WRG/SPC CH A
Fault Code:
2730207STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Stall Protection Computer (SPC) Channel A or Channel B shows that the pitch disconnect lock does not lock when commanded to lock by the SPC or stays locked when commanded to unlock by the SPC.
Possible Causes:
- Pitch Disconnect Lock Solenoid (L50)
- Secondary Power Distribution Assembly (SPDA) 1 (A13)
- Stall Protection Computer (SPC) (A40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-27-0363 - No Fault Found initiative: Stall Protection Computer
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Lock Solenoid | AMM 27-31-09-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Lock Solenoid | AMM 27-31-09-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between Stall Protection Computer and lock solenoid and Control panel.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Swap SPDA 1 with SPDA 3. Is the fault still present?
- If NO, replace SPDA 1 and do close out.
- If YES, continue with next step.
- Replace the lock solenoid. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the SPC.
- Do close out.