Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/25/19

Message Overview:

Fault Message:

BMC#1/BMC#2[WAI]/SPC CH A

Fault Code:

2730212STL

Associated CAS:

STALL WARN ADVANCE
(Caution)

STALL WARN ADVANCE
(Advisory)

Reporting LRU: Stall Protection Computer (SPC)
System Description: 27-32-00
Schematic Diagram: 27-32-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-32-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Stall Protection Computer (SPC) Channel A does not receive WAI signals from Bleed Management Controller (BMC).

Possible Causes:

  • Bleed Management Controller (BMC) 1 (A69)
  • Bleed Management Controller (BMC) 2 (A70)
  • Stall Protection Computer (SPC) (A40)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Stall Protection Computer AMM 27-32-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Stall Protection Computer AMM 27-32-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Ice Detectors AMM 30-81-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Ice Detectors AMM 30-81-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Bleed Management Controller AMM 36-11-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Bleed Management Controller AMM 36-11-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. On CAIMS PMAT, check active faults for BMC 1 and BMC 2. Troubleshoot them first.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. On CAIMS PMAT, get access to System Diagnostics, ATA 27-00, SPC A, LRU TEST, Discrete inputs for the ice detector status input the SPC A. Troubleshoot ice detector faults first if there is any.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Perform wiring checks between BMCs, ice detectors and SPC.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  4. Replace Stall Protection Computer (SPC).
  5. Do close out.