Message Overview:
Fault Message:
SFCU#1/SFCU#2[SLATS]/SPC CH A
Fault Code:
2730213STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Stall Protection Computer (SPC) CH A does not receive the SLAT signal from SLAT/FLAP Control Unit (SFCU) 1 or SFCU 2.
Possible Causes:
- Slat/Flap Control Unit (SFCU) 1 (A124)
- Slat/Flap Control Unit (SFCU) 2 (A95)
- Stall Protection Computer (SPC) (A40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-27-0363 - No Fault Found initiative: Stall Protection Computer
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electronic Rigging of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-820-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Verify that the STALL WARN ADVANCE (amber) EICAS message is displayed on power-up.
- Using the PMAT, access CAIMS to view active or stored faults related to SFCU 1 and SFCU 2.
- If a fault(s) is reported, go to step 4.
- If there is no fault reported, continue with next step.
- Perform the electronic rigging of the SLAT and FLAP control system. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Troubleshoot and any clear flap system fault using the associated SmartFix Plus troubleshooting page. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap SFCU 1 with SFCU 2. Is the fault still present on the same channel?
- If YES, continue with next step.
- If NO, replace defective SFCU.
- Perform wiring checks between both SFCUs and the SPC.
- If wiring defects are found, repair defective wiring as required and do close out.
- If no defects are found, continue with next step.
- Replace the Stall Protection Computer (SPC).
- Do close out.