Message Overview:
Fault Message:
SHAKER #2/WRG/SPC CH B
Fault Code:
2731206STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Channel B of the Stall Protection Computer (SPC) senses a Shaker 2 low current or an over current condition. The error can be found during continuous BIT or a PAT.
Possible Causes:
- Stick Shaker 2 (A204)
- Stall Protection Computer (SPC) (A40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Stick Shakers | AMM 27-32-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stick Shakers | AMM 27-32-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Make sure the connector (A204) and the wires connect on the stick shaker 2 are not damaged.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Measure the ground return at the Stick Shaker 2 A204P1-B.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Remove the Stall Protection Computer; inspect the tray, connector and the pins at the connector tray.
- Measure the 28 VDC at the SPC from the SPDA.
- Reinstall the SPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: The SPC is difficult to install due to its location.
- Replace Stick Shaker 2.
NOTE: If possible, swap the stick shaker 1 and 2 and confirm that the fault follows the shaker 1 in 2 positions - Do close out.