06/25/19
Message Overview:
Fault Message:
BMC#1/BMC#2[WAI]/SPC CH B
Fault Code:
2731212STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Stall Protection Computer (SPC) channel B does not receive WAI signals from Bleed Management Controller (BMC).
Possible Causes:
- Bleed Management Controller (BMC) 1 (A69)
- Bleed Management Controller (BMC) 2 (A70)
- Stall Protection Computer (SPC) (A40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Ice Detectors | AMM 30-81-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ice Detectors | AMM 30-81-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On CAIMS PMAT, check active faults for BMC 1 and BMC 2. Troubleshoot them first.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- On CAIMS PMAT, get access to System Diagnostics, ATA 27-00, SPC B, LRU TEST, Discrete inputs for the ice detector status input the SPC B. Troubleshoot ice detector faults first if there is any.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between BMCs, ice detectors and SPC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace stall protection computer (SPC).
- Do close out.