Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/02/19

Message Overview:

Fault Message:

DISCRETE INTERFACE ERROR #1/2/3

Fault Code:

2751048STD

Associated CAS:

None

Reporting LRU: Slat/Flap Control Unit (SFCU)
System Description: 27-51-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-07 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-08 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

One or more of the discrete outputs from the Slat/Flap Control Unit (SFCU) that follow are defective:

  • MOVING
  • MOVING 2
  • FLAPS NOT ZERO

Possible Causes:

  • Slat/Flap Control Unit (SFCU) 1 (A124)
  • Slat/Flap Control Unit (SFCU) 2 (A95)
  • Flight Control Unit (FCU) 1 (A65)
  • Flight Control Unit (FCU) 2 (A66)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Slat/Flap Control System AMM 27-51-00-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electronic Rigging of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-820-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the External Avionics-Compartment Access-Panel (140BB) AMM 52-45-11-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the External Avionics-Compartment Access-Panel (140BB) AMM 52-45-11-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Torquing Procedures - System Description SPM 20-20-00-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SFCU 1 with SFCU 2.

    1. If system checks are good, replace SFC 1 and do close out.
    2. If fault remains, continue with next step.

  2. Perform the rigging of the slat/flap control system. Set the selection to a new detent position on the slat/flap control handle and move the system to the new position.

    1. If the fault occurs again on the same channel, continue with this procedure.
    2. If the fault occurs on the opposite channel, the fault has moved with the controller. Replace the defective SFCU and do close out.
      NOTE: SFCU 1 is the left side (channel 1) controller. SFCU 2 is the right side (channel 2) controller.

  3. Disconnect the connectors A124AP1 for the SFCU 1 (A124), A95AP1 for the SFCU 2 (A95), A65FP1 for the FLIGHT CONTROL UNIT 1 (A65), A66FP1 for the FLIGHT CONTROL UNIT 2 (A66), A63P1 and A63P2 for the D.C. POWER CENTRE (A63). Perform a continuity check as follows:
    For the SFCU1:

    From To Result
    A124AP1-94 A65FP1-1
    A124AP1-16 A63P1-M
    A124AP1-15 A79P1-EE

    For the SFCU2:

    From To Result
    A95AP1-94 A66FP1-1
    A95AP1-16 A63P2-k
    A95AP1-15 A79P1-FF

    1. If there is continuity, continue with next step.
    2. If there is no continuity, repair defective wiring as required and do close out.

  4. Perform a continuity check as follows:
    For the SFCU1:

    From To Result
    A124AP1-94 Ground
    A124AP1-16 Ground

    For the SFCU2:

    From To Result
    A95AP1-94 Ground
    A95AP1-16 Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  5. Replace the defected FCU.
  6. Do close out.