Message Overview:
Fault Message:
ANALOG OUT FLAP/ SPC/ SFCU#1
Fault Code:
2751255STD
Associated CAS:
| Reporting LRU: | Slat/Flap Control Unit (SFCU) 1 |
| System Description: | 27-52-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Flap analog output voltage from the Slat/Flap Control Unit (SFCU) 1 to the Stall Protection Computer (SPC) is out of range.
Possible Causes:
- Slat/Flap Control Unit (SFCU) 1 (A124)
- Stall Protection Computer (SPC) (A40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SFCU 1 with SFCU 2.
- If system checks are good, replace SFCU 1 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between the applicable SFCU and SPC as follow:
From To Result A124AP1-85 A40AP1-53 A124AP1-86 A40AP1-67 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace SPC.
- Do close out.