Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/02/19

Message Overview:

Fault Message:

FLAP RESOLVER EXCITATION/SFCU#1/WRG

Fault Code:

2751257STD

Associated CAS:

None

Reporting LRU: Slat Flap Control Unit (SFCU) 1
System Description: 27-52-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

When one of the following conditions occurs:

  • The output voltage is not within the permitted range
  • The output current is not within the permitted range

Possible Causes:

  • Slat Flap Control Unit (SFCU) 1 (A124)
  • Flap Resolver
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Flap Resolvers AMM 27-52-49-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flap Resolvers AMM 27-52-49-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. On the EMS CDU, select CTRL function and SLAT/FLAP RESET.
    NOTE: Wait at least one minute after SFCU reset to allow self-test to run.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Swap SFCU 1 with SFCU 2.

    1. If system checks are good, replace SFCU 1 and do close out.
    2. If fault remains, continue with next step.

  3. Check resistance value as follows:
    From left flap resolver:

    From To Resistance Value Result
    A124AP1-96 A124AP1-95 13 to 24 ohms

    From right flap resolver:

    From To Resistance Value Result
    A124AP1-82 A124AP1-81 13 to 24 ohms

    NOTE: Performing this resistance check will verify the interface wiring in addition to the resolver.

    1. If resistance is within tolerance, go to step 6.
    2. If resistance checks are out of tolerance, continue with next step.

  4. Perform a resistance check of the resolver as follows:
    From left flap resolver:

    From To Resistance Value Result
    MT67J1-2 MT67J1-1 13 to 24 ohms

    From right flap resolver:

    From To Resistance Value Result
    MT72J1-2 MT72J1-1 13 to 24 ohms

    1. If resistance of the resolver is out of tolerance, go to step 6.
    2. If resistance of the resolver is within tolerance, continue with next step.

  5. Perform wiring checks between the applicable SFCU and resolver.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  6. Replace resolver.
  7. Do close out.