Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/02/19

Message Overview:

Fault Message:

RVDT EXCITATION/ SFCH/ SFCU#1/ WRG

Fault Code:

2751259STD

Associated CAS:

None

Reporting LRU: Slat Flap Control Unit (SFCU) 1
System Description: 27-51-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

When one of the following conditions occurs:

  • The output voltage is not within the permitted range
  • The output current is not within the permitted range

Possible Causes:

  • Slat Flap Control Unit (SFCU) 1 (A124)
  • Slat/Flap Control Handle (SFCH)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

There are alternative ways to clear the fault:

On the EMS CDU, select CTRL function and SLAT/FLAP RESET.

NOTE: Wait at least one minute after SFCU reset to allow self-test to run.

Quick Links:

Removal of the SLAT/FLAP Selector Handle AMM 27-51-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the SLAT/FLAP Selector Handle AMM 27-51-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SFCU 1 with SFCU 2.

    1. If system checks are good, replace SFCU 1 and do close out.
    2. If fault remains, continue with next step.

  2. Remove the SFCU and perform resistance check between the flap RVDT and SFCU as follows:
    From FH RVDT one:

    From To Resistance Value Result
    A124AP1-28 A124AP1-27 29 to 41 ohms

    From FH RVDT two:

    From To Resistance Value Result
    A124AP1-41 A124AP1-40 29 to 41 ohms

    NOTE: Performing this resistance check will verify the interface wiring in addition to the resolver.

    1. If resistance is within tolerance, go to step 4.
    2. If resistance checks are out of tolerance, continue with next step.

  3. Perform a resistance check of the RVDT as follows:
    From FH RVDT one:

    From To Resistance Value Result
    MT79J1-2 MT79J1-1 29 to 41 ohms

    From FH RVDT two:

    From To Resistance Value Result
    MT79J1-8 MT79J1-7 29 to 41 ohms

    1. If resistance of the Slat/Flap control handle is within tolerance, repair defective wiring as required and do close out.
    2. If resistance of the Slat/Flap control handle is out of tolerance, continue with next step.

  4. Replace SFCH.
  5. Do close out.