Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/03/19

Message Overview:

Fault Message:

RVDT EXCITATION/ SFCH/ SFCU#2/ WRG

Fault Code:

2752259STD

Associated CAS:

None

Reporting LRU: Slat/Flap Control Unit (SFCU) 2
System Description: 27-51-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

When one of the following conditions occurs:

  • The output voltage is not within the permitted range
  • The output current is not within the permitted range

Possible Causes:

  • Slat Flap Control Unit (SFCU) 2 (A95)
  • Slat Flap Selector Handle (SFSH) (MT79)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

There are alternative ways to clear the fault:

On the EMS CDU, select CTRL function and SLAT/FLAP RESET.

NOTE: Wait at least one minute after SFCU reset to allow self-test to run.

Quick Links:

Removal of the SLAT/FLAP Selector Handle AMM 27-51-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the SLAT/FLAP Selector Handle AMM 27-51-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SFCU 2 with SFCU 1.

    1. If system checks are good, replace SFCU 2 and do close out.
    2. If fault remains, continue with next step.

  2. Remove the SFCU and perform resistance check between the flap RVDT and SFCU as follows:
    NOTE: Performing this resistance check will verify the interface wiring in addition to the resolver.

    Source From To Expected Result Result
    from FH RVDT one A95AP1-28 A95AP1-27 29 to 41 ohms
    from FH RVDT two A95AP1-41 A95AP1-40 29 to 41 ohms

    1. If resistance checks are out of tolerance, repair defective wiring as required and do close out.
    2. If resistance checks are within tolerance, continue with next step.

  3. Perform a resistance check of the resolver as follows:

    Source From To Expected Result Result
    FH RVDT one MT79J2-8 MT79J2-7 29 to 41 ohms
    FH RVDT two MT79J2-8 MT79J2-7 29 to 41 ohms

    1. If resistance of the resolver is within tolerance, do close out.
    2. If resistance checks are out of tolerance, continue with next step.

  4. Replace SFSH.
  5. Do close out.