Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/03/19

Message Overview:

Fault Message:

LVDT EXCITATION/ SFCU#2/ WRG

Fault Code:

2752260STD

Associated CAS:

None

Reporting LRU: Slat/Flap Control Unit (SFCU) 2
System Description: 27-51-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

When one of the following conditions occurs:

  • The output voltage is not within the permitted range
  • The output current is not within the permitted range

Possible Causes:

  • Linear Variable Displacement Transducer (LVDT) (MT73)
  • Linear Variable Displacement Transducer (LVDT) (MT74)
  • Linear Variable Displacement Transducer (LVDT) (MT75)
  • Linear Variable Displacement Transducer (LVDT) (MT76)
  • Slat Flap Control Unit (SFCU) 2 (A95)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

NOTE: You may attempt to clear the fault: On the EMS CDU, select CTRL function and SLAT/FLAP RESET. Wait at least one minute after SFCU reset to allow self-test to run.

Quick Links:

Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Flap Skew Sensor AMM 27-52-45-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flap Skew Sensor AMM 27-52-45-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove SFCU 2 and perform a resistance check between the flap LVDTs and the SFCU as follows:
    NOTE: Performing this resistance check will verify the Associated Wiring in addition to the resolver.
    LVDT 1:

    From To Expected Result Result
    A95CP1-37 A95CP1-25 120 to 150 Ohms
    A95CP1-54 A95CP1-67 250 to 280 Ohms
    A95CP1-54 A95CP1-66 110 to 130 Ohms
    A95CP1-67 A95CP1-66 140 to 160 Ohms

    LVDT 2:

    From To Expected Result Result
    A95CP1-36 A95CP1-24 120 to 150 Ohms
    A95CP1-14 A95CP1-27 250 to 280 Ohms
    A95CP1-14 A95CP1-15 110 to 130 Ohms
    A95CP1-27 A95CP1-15 140 to 160 Ohms

    LVDT 3:

    From To Expected Result Result
    A95CP1-35 A95CP1-23 120 to 150 Ohms
    A95CP1-29 A95CP1-42 250 to 280 Ohms
    A95CP1-29 A95CP1-41 110 to 130 Ohms
    A95CP1-42 A95CP1-41 140 to 160 Ohms

    LVDT 4:

    From To Expected Result Result
    A95CP1-48 A95CP1-49 120 to 150 Ohms
    A95CP1-39 A95CP1-52 250 to 280 Ohms
    A95CP1-39 A95CP1-51 110 to 130 Ohms
    A95CP1-52 A95CP1-51 140 to 160 Ohms

    1. If all resistance values are within tolerance, go to step 3.
    2. If one or more measurement is out of tolerance, continue with next step.

  2. Access and remove the associated LVDT. Perform a wiring check between SFCU 2 and the associated LVDT. Check for end to end continuity and for short circuit to ground.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, replace the defective LVDT and do close out.

  3. Replace SFCU 2.
  4. Do close out.