06/26/19
Message Overview:
Fault Message:
PITCH FEEL ACTR #2 POT/WRG FAULT
Fault Code:
27653192SX
Associated CAS:
| Reporting LRU: | Flight Control Unit (FCU) 2 |
| System Description: | 27-33-00 |
| Schematic Diagram: | 27-33-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-33-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
There is a problem with a Potentiometer in a Pitch Feel Actuator 2. The Potentiometer is possibly invalid or reporting a mechanical jam.
Possible Causes:
- Pitch Feel Actuator 2 (A78)
- Flight Control Unit (FCU) 2 (A66)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
This fault may sometime be cleared by performing the flight control system reset procedure. If the message comes back more then once within 10 flight legs, troubleshooting is required.
NOTE: If FCUs are swapped/replaced, ensure proper system tests are carried out to clear latched faults retained in the FCU prior to swap.
The pitch feels actuator information can be found in the CAIMS system diagnostic:
- SYSTEM DIAG
- 27-00 FLIGHT CONTROLS
- FLIGHT CONTROL UNIT #1
- LRU TEST
- DISPLAY PITCH FEEL DATA
- CONFIRM
The Pitch feel Actuator can also be simulated on CAIMS in case the fault cleared:
Quick Links:
| Removal of the Pitch Feel Actuators | AMM 27-33-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pitch Feel Actuators | AMM 27-33-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap FCU 2 with FCU 1 and reset FCUs latched faults.
- If system checks are good, replace FCU 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between FCU 2 and pitch feel actuator 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace pitch feel actuator 2.
- Do close out.