background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/03/19

Message Overview:

Fault Message:

FLT CONT 1B FAULT[PWR-ON SELF TEST]

Fault Code:

27653281SX

Associated CAS:

FLT SPOILERS FAIL
(Caution)

FLT SPOILERS FAULT
(Advisory)

Reporting LRU: Flight Control Unit (FCU) 1
System Description: 27-60-00
Schematic Diagram: 27-60-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: None

Fault Description:

Failure occurred during computer power up test. One or two flight control channel from the Flight Control Unit 1 is invalid.

Possible Causes:

  • Flight Control Unit (FCU) 1 (A65)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Magenta cross is displayed on Spoilers Synoptic, with 'FLT SPOILER FAULT' Advisory message if one pair of spoilers are affected. 'FLT SPOILER FAIL' Caution message will be posted if two FCM affected.

Quick Links:

Removal of the Flight-Control Units AMM 27-61-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flight-Control Units AMM 27-61-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Replace FCU 1 and reset FCUs latched faults.
  2. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.