07/04/19
Message Overview:
Fault Message:
AIR DATA COMPTR #2 FAULT [FCU 1]
Fault Code:
27654241SX
Associated CAS:
| Reporting LRU: | Flight Control Unit (FCU) 2 |
| System Description: | 34-11-00 |
| Schematic Diagram: | 34-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-11-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Flight Control Unit (FCU) 1 does not receive data from Air Data Computer (ADC) 2.
Possible Causes:
- Air Data Computer (ADC) 2 (A28)
- Flight Control Unit (FCU) 1 (A65)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Side Console Trim-Panels (221EZ/222EZ, 221FZ/222FZ, 221TZ/222TZ) |
AMM 25-12-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Side Console Trim-Panels (221EZ/222EZ, 221FZ/222FZ, 221TZ/222TZ) |
AMM 25-12-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) |
AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove FCU 1 to get access to electrical connector A65AP1. Disconnect ADC 2 connector A28P1. Perform a continuity check as follows:
From To Result A65AP1-11G A28P1-60 A65AP1-11F A28P1-61 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A65AP1-11G Ground A65AP1-11F Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap FCU 1 with FCU 2. Is the fault still present?
- If NO, replace FCU 1 and do close out.
- If YES, continue with next step.
- Replace ADC 2.
- Do close out.