07/05/19
Message Overview:
Fault Message:
PLT ROLL CTL IN MDL XDCR/WRG FAULT
Fault Code:
27655270SX
Associated CAS:
| Reporting LRU: | Flight Control Unit (FCU) |
| System Description: | 27-60-00 |
| Schematic Diagram: | 27-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-60-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
There is a problem with the Pilot's Roll Control Input Module (RCIM).
Possible Causes:
- Pilot Roll Control Input Module (RCIM) (MT133)
- Flight-Control Unit (FCU) 1 (A65)
- Flight-Control Unit (FCU) 2 (A66)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None.
Forum Articles/Infoservice/Newsletter: None
The pilot Roll input control module positions can be found in CAIMS:
Quick Links:
| Functional Test of the Aileron Control System | AMM 27-11-00-720-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Roll Control Input-Module | AMM 27-11-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Roll Control Input-Module | AMM 27-11-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check FCUs that reports this fault.
- If fault reported by both FCUs, go to step 3.
- If fault reported by one FCU, continue with next step.
- Swap FCUs.
- If system checks are good, replace the defective FCU. Reset FCUs latched faults and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between FCUs reporting the fault and Pilot RCIM (MT133).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Pilot RCIM.