Message Overview:
Fault Message:
PLT ROLL CTL IN MDL FAULT [FCU2]
Fault Code:
27655282SX
Associated CAS:
| Reporting LRU: | Flight-Control Units (FCU) 2 |
| System Description | 27-60-00 |
| Schematic Diagram | 27-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram | 27-60-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
There is a problem with the pilot’s Roll Control Input Module (RCIM).
Possible Causes:
- Roll Control Input Module (RCIM) (MT133)
- Flight-Control Units (FCU) 2 (A66)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Functional Test of the Aileron Control System | AMM 27-11-00-720-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Roll Control Input-Module | AMM 27-11-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Roll Control Input-Module | AMM 27-11-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Self-Test (SPOST) of the Flight-Control Units | AMM 27-61-05-740-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) | AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) | AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the FCU 2 to get access to the electrical connectors A66EP1 and A66BP1 and disconnect the pilot RCIM electrical connector MT133P1. Perform a continuity check as follows:
From To Result A66BP1-6C MT133P1-7 A66BP1-5C MT133P1-13 A66BP1-5D MT133P1-8 A66EP1-12B MT133P1-10 A66EP1-12A MT133P1-9 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A66BP1-6C Ground A66BP1-5C Ground A66BP1-5D Ground A66EP1-12B Ground A66EP1-12A Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap FCU 2 with FCU 1. Is the fault still present?
- If NO, replace FCU 2 and do close out.
- If YES, continue with next step.
- Replace the RCIM.
- Do close out.