background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/09/19

Message Overview:

Fault Message:

DATA ACQ UNIT #1/ GP BUS FAULT

Fault Code:

27660211SX

Associated CAS:

None

Reporting LRU: Data Acquisition Unit (DAU) 1
System Description: 27-60-00
Schematic Diagram: 27-60-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-60-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

There is a Data Acquisition Unit (DAU) 1 failure.

Possible Causes:

  • Data Acquisition Unit (DAU) 1 (A17)
  • Flight Control Unit (FCU) 1 (A65)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Flight-Control Units AMM 27-61-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flight-Control Units AMM 27-61-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform wiring checks between FCU 1 (A65DP1) and DAU 1 (A17CP1).

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  2. Swap FCU 1 with FCU 2 and reset FCUs latched faults.

    1. If system checks are good, replace FCU 1 and do close out.
    2. If fault remains, continue with next step.

  3. Replace DAU 1.
  4. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.