07/18/19
Message Overview:
Fault Message:
None
Fault Code:
28200843
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-22-00 |
| Schematic Diagram: | 28-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] 28-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-20-03 [ Global Express ] [ G5000 ] [ Global XRS ] 28-22-02 [ Global Express ] [ G5000 ] [ Global XRS ] 28-41-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
When the conditions that follow occur:
- Left or Right Center Transfer Pump is commanded ON, but it is failed OFF and the pump is covered in fuel.
- Left or Right wing quantity is less than 50% full and the on side pump is inoperative when the center tank is not empty.
Possible Causes:
- Portable Maintenance Access Terminal (PMAT)
- Fuel Management Quantity and Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW 700-28-0072 - Center Tank Fuel Transfer Pump
Forum Articles/Infoservice/Newsletter: None
NOTE: Wings need to be filled above 50% and the center tank filled to at least 1000 lbs. before proceeding with any of the following.
- In CAIMS go to:
- System Diagnostics
- Chapter 28-00 Fuel
- Computer (FMQGC Channel A or B)
- LRU test
- Center Transfer Channel A or B
- Turn on/off left than right pump to verify pump operation.
- If both pumps operate, exit CAIMS and proceed to next step.
- Apply External Power.
- In Flight compartment on the APU Control Panel make sure switch is in the off position.
- On the throttle quadrant, put the Left and Right Engine Run switches to on.
- Make sure you see the following indication:
- Center Tank L/R XFER Pump
- Green L/R Transfer Line - Green
- Transfer will cease at approximately 250lbs.
Quick Links:
| Operational Test of the Center Transfer Pumps | AMM 28-22-00-710-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Portable Maintenance-Access Terminal (PMAT) | AMM 45-45-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Portable Maintenance-Access Terminal (PMAT) | AMM 45-45-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Is the Left or Right wing quantity less than 50% full when the on side pump failed and the center tank is not empty?
- If YES, re-distribute wing/center tank fuel load.
- If NO, continue with next step.
- Is CAS message gone?
- If YES, do close out.
- If NO, continue with next step.
- Refer to AW 700-28-0072 to determine if the failure is a known issue.
- If YES, follow instructions of AW700-28-0072 and continue with next step.
- If NO, go to step 5.
- Perform operation test of center transfer pumps. Is test passed?
- If YES, do close out.
- If NO, continue with next step.
- Replace FMQGC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform a wiring checks between FMQGC and PMAT.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace PMAT.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Troubleshooting using CAIMS message.
- Do close out.