Message Overview:
Fault Message:
COCKPIT RDCP/WRG
Fault Code:
2844603PK
Associated CAS:
| Reporting LRU: | Fuel Management Quantity and Gauging Computer (FMQGC) |
| System Description: | 28-23-00 |
| Schematic Diagram: | 28-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-23-01 [ Global Express ] [ G5000 ] [ Global XRS ] 24-00-14 [ Global Express ] [ G5000 ] [ Global XRS ] 24-00-14 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Fuel Management Quantity and Gauging Computer (FMQGC) cannot sense the REFUEL/DEFUEL Control Panel (RDCP) data busses.
Possible Causes:
- Junction Box (JB6)/PCB1
- Junction Box (JB6)/PCB3
- Auxiliary Power Unit (APU) Start Contactor Assembly (ACSA) (A48)
- Refuel/Defuel Control Panel (RDCP) (A46)
- Refuel/Defuel Control Panel (RDCP) (A213)
- Fuel Management Quantity and Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB6 Circuit-Cards | AMM 24-00-14-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB6 Circuit-Cards | AMM 24-00-14-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the REFUEL/DEFUEL Control Panel | AMM 28-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the REFUEL/DEFUEL Control Panel | AMM 28-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Refuel/Defuel Control Panel | AMM 28-23-01-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect the connector A213P1 from the REFUEL/DEFUEL control panel. In the front spar RH on the REFUEL/DEFUEL control panel, set the switch START-STOP/SOV TEST to START and Perform a check for 28 ±2 VDC on the wiring side as follows:
From To Result A213P1-12 A213P1-13 28 ±2 VDC - If there is 28 ±2 VDC, continue with step 6.
- If there is no 28 ±2 VDC, continue with next step.
- Disconnect the connector A48P1 from the ASCA and perform a check for 28 ±2 VDC on the LRU side as follows:
From To Result A48P1-T A48P1-U 28 ±2 VDC - If there is no 28 ±2 VDC, perform a troubleshooting for "DC/Batt Bus Isolated".
- If there is 28 ±2 VDC, continue with next step.
- Perform a continuity check as follows:
From To Result A48P1-T JB6EP1-59 A48P1-U JB6BP1-41 JB6EP1-56 A213P1-13 JB6DP1-6A A213P1-12 A213P1-16 GS906 A213P1-17 GS907 A213P1-18 GS908 A213P1-19 GS909 - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Check the relay K1 operation in the circuit-card 3 test points (refer to WM 24-00-14 sheet 8).
- If it is defective, replace the circuit-card 3 from JB6 and do close out.
- If it is not defective, continue with next step.
- Check the relay K8 operation in the circuit-card 1 test points (refer to WM 24-00-14 sheet 1).
- If it is defective, replace the circuit-card 1 from JB6 and do close out.
- If it is not defective, continue with next step.
- Perform a continuity check as follows:
From To Result A213P1-4 A47EP1-A11 A213P1-5 A47EP1-A12 A213P1-6 A47EP1-C11 A213P1-7 A47EP1-C12 A213P1-8 A47EP1-E11 A213P1-9 A47EP1-E12 A213P1-10 A47EP1-G11 A213P1-11 A47EP1-G12 A47FP1-12 JB6BP1-35 A47CP1-E1 JB6BP1-37 A47FP1-11 GS43 A47FP1-17 GS43 - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, replace the REFUEL/DEFUEL control panel and continue with next step.
- Check if the fault message "COCKPIT REFUEL/DEFUEL PANEL/WRG FLT" is still present.
- If NO, do close out.
- If YES, continue with next step.
- Perform a continuity check as follows:
From To Result A46P1-4 A47EP1-A14 A46P1-5 A47EP1-A15 A46P1-6 A47EP1-C14 A46P1-7 A47EP1-C15 A46P1-8 A47EP1-E14 A46P1-9 A47EP1-E15 A46P1-10 A47EP1-G14 A46P1-11 A47EP1-G15 A47FP1-12 JB6BP1-35 A47CP1-E1 JB6BP1-37 A47FP1-11 GS43 A47FP1-17 GS43 - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace the FMQGC.
- Do close out.