background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/12/19

Message Overview:

Fault Message:

RH AFT AC BOOST PUMP/PRESS SW/WRG

Fault Code:

2844608PK

Associated CAS:

R PRI FUEL PUMPS
(Caution)

R PRI FUEL PUMP
(Advisory)

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-22-00
Schematic Diagram: 28-22-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-22-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

R AFT AC BST PUMP/PRES SWITCH/WRG FL shows on the CAIMS Portable Maintenance Access Terminal (PMAT) when the conditions that follow occur:

  • The Right Aft Pump command is on
  • The Right Aft Pump pressure-indication is low

OR

  • The Right Aft Pump command is off
  • The Right Aft Pump pressure-indication is high

NOTE: If both of the CAIMS messages R AFT AC BST PUMP/PRES SWITCH/WRG FL and R AFT AC BOOST PUMP LMS/WRG FAULT show, troubleshoot with R AFT AC BOOST PUMP LMS/WRG FAULT page first.

Possible Causes:

  • Right Aft AC Boost Pump Pressure-Switch (S16)
  • Right Aft AC Boost Pump Catridge (B23)
  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • Right Aft Pump Canister
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the AC Boost-Pump Pressure-Switches AMM 28-21-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Boost-Pump Pressure-Switches AMM 28-21-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove the FMQGC and inspect all connectors and pins on the unit and A/C side. Rerack the FMQGC and make sure it is fully and properly pushed into place. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  2. Perform a wiring check between the right aft AC boost pump pressure switch and the FMQGC. Look for continuity, short circuit and high resistance.

    1. If wiring checks are not good, repair defective wiring as required and do close out
    2. If wiring checks are good, continue with next step.

  3. Swap the right aft AC boost pump pressure switch with the right fwd AC boost pump pressure switch. Is the fault message still present?

    1. If NO, replace right aft AC boost pump pressure switch and do close out.
    2. If YES, continue with next step.

  4. Replace the FMQGC.
  5. Do close out.