background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/12/19

Message Overview:

Fault Message:

RH AFT AC BOOST PUMP ELECT PWR/WRG

Fault Code:

2844609PK

Associated CAS:

R PRI FUEL PUMPS
(Caution)

R PRI FUEL PUMP
(Advisory)

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-22-00
Schematic Diagram: 28-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-22-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

R AFT AC BOOST PUMP LMS/WRG FAULT shows when the conditions that follow occur:

  1. The R WING FEED INHIBIT PRI PUMP Switch on the Fuel Control Panel is not set to OFF.
  2. The Right Engine is on, the Right Engine is on with the Cross-Feed Valve open, or the Auxiliary Power Unit (APU) is on.
  3. The Right Aft Boost-Pump pressure is low.
  4. The aircraft has a pitch angle of more than -1 degree.
  5. The Electrical Management System (EMS)/AC Power Center (ACPC) has a failure.

OR

  1. The R WING FEED INHIBIT PRI PUMP Switch on the Fuel Control Panel is set to OFF.
  2. The Right Engine and the APU are off and the Left Engine is not on with the Cross-Feed Valve open.
  3. The Right Aft Boost-Pump Pressure is high.
  4. The EMS/ACPC has a failure.

Possible Causes:

  • AC Power Center (ACPC)/Solid-State Power Controller (SSPC) 10
  • AC Power Center (ACPC) Secondary Logic Card (SLC)
  • Right AFT AC Boost Pump Catridge (B23)
  • Fuel Management Quantity and Gauging Computer (FMQGC) (A47)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Solid-State Power Controller AMM 24-51-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Solid-State Power Controller AMM 24-51-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Boost-Pump Cartridges AMM 28-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Boost-Pump Cartridges AMM 28-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Select the ACPC A (B) LOAD STATUS LABEL 017, LOAD 2 (R AFT PRI PUMP, Phase A) page, via CAIMS on the PMAT. Set the right ENGINE RUN swith to ON and the R PRIM PUMPS switch/light to ON (Pushed out). Make sure the result that follows are met:

    Reference Status
    LOGIC EQUATION STATE (L TRANSFER REQUEST) ON
    VIRTUAL CIRCUIT BREAKER (SSPC CIRCUIT BREAKER) IN
    VIRTUAL SWITCH (SSPC SW) ON
    LOCK STATE UNLOCKED
    VOLTAGE STATUS PRESENT
    CURRENT STATUS FLOWING
    TRIP STATUS (CIRCUIT BREAKER) NOT TRIP
    FAIL STATUS (SSPC) NOT FAILED

    1. If the above status are met, go to step 8.
    2. If one of the above status is not met, go to step 3.
    3. If more than one status is not met, continue with next step.
      NOTE: Repeat this step by selecting LABEL 020 Load 1 (R AFT PRI PUMP, Phase B) and LABEL 020 Load 2 (R AFT PRI PUMP, Phase C).

  2. An alternative way of monitoring the result is to select ACPC IN via EMS CDU1 or CDU2 signboard Menu:

    Left Column Center Column
    Label 017 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
    1 1 1 1 1 1
    Reference R AFT PRIM PUMP Phase A
    Label 020 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
    1 1 1 1 1 1 1 1 1 1 1 1
    R AFT PRIM PUMP Phase C R AFT PRIM PUMP Phase B

    • Bit 14 or 22:LOGIC EQUATION STATE (L TRANSFER REQUEST)
    • Bit 15 or 23:VIRTUAL CIRCUIT BREAKER (SSPC CIRCUIT BREAKER)
    • Bit 16 or 24:VIRTUAL SWITCH (SSPC SW)
    • Bit 17 or 25:LOCK STATE
    • Bit 18 or 26:VOLTAGE STATUS
    • Bit 19 or 27:CURRENT STATUS
    • Bit 20 or 28:TRIP STATUS (CIRCUIT BREAKER)
    • Bit 21 or 29:FAIL STATUS (SSPC)

    1. If the above status are met, go to step 8.
    2. If one of the above status is not met, continue with next step.

  3. Perform wiring check (short to ground=fail) between the ACPC (A54P1) and right wing aft AC boost-pump (B23P1).

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  4. Perform a ground check at left wing aft AC boost-pump (B23J1). Repair as required.

    1. If ground is not there, go to step 6.
    2. If ground is there, continue with next step.

  5. Swap the Right Wing AC boost-pump with Left Wing AC boost pump. Is the fault still present?

    1. If NO, replace Right Wing AC boost-pump and do close out.
    2. If YES, continue with next step.

  6. Swap the ACPC/SSPC 10. Is the fault still present?

    1. If NO, replace ACPC/SSPC 10 and do close out.
    2. If YES, continue with next step.

  7. Swap the ACPC secondary logic card. Is the fault still present?

    1. If NO, replace defective ACPC secondary logic card card and do close out.
    2. If YES, continue with next step.

  8. Remove the FMQGC. Re-install the FMQGC making sure it is fully and properly inserted into place. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  9. Replace the FMQGC.
  10. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.