07/12/19
Message Overview:
Fault Message:
APU FEED SOV/WRG
Fault Code:
284461BPK
Associated CAS:
| Reporting LRU: | Fuel Management Quantity and Gauging Computer (FMQGC) (A47) |
| System Description: | 28-21-00 |
| Schematic Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Auxiliary Power Unit (APU) FEED VALVE/WRG FAULT shows when the conditions that follow occur:
- The APU Fire-Handle is pulled, or the APU is not on.
- The APU-Feed Shutoff-Valve Indication is open.
OR
- APU Fire-Handle is not pulled.
- The APU is on.
- The APU-Feed Shutoff-Valve Indication is closed.
Possible Causes:
- Auxiliary Power Unit (APU) Feed Shutoff-Valve Actuator (L40)
- Junction Box (JB4)
- Auxiliary Power Unit (APU) Fire-Handle (A211)
- Fuel Management Quantity and Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU Feed Shutoff-Valve | AMM 28-21-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Feed Shutoff-Valve | AMM 28-21-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU-Feed Shutoff-Valve Actuator | AMM 28-21-41-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU-Feed Shutoff-Valve Actuator | AMM 28-21-41-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
NOTE: The APU Feed Valve is powered to the closed position.
- Access the APU Feed SOV and disconnect connector L40P1. Did the valve remain closed?
- If YES, suspect the valve or the valve actuator for failure and replace as required and do close out.
- If NO, continue with next step.
- Disconnect JB4 connector JB4AP1. Perform a wiring check as follows:
From To Result L40P1-B Ground L40P1-D Ground L40P1-B L40P1-D - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring check as follows:
From To Result L40P1-B JB4BP1-41 L40P1-D JB4BP1-31 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a wiring check between the APU FIREX Handle and the FMQGC and make sure the handle is providing a ground to the FMQGC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace relay K29 on PCB 3 of JB4. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace FMQGC.
- Do close out.