Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/17/19

Message Overview:

Fault Message:

RH REFUEL SOV SOLENOID/WRG

Fault Code:

284463EPK

Associated CAS:

R RD VALVE OPEN
(Advisory)

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-23-00
Schematic Diagram: 28-23-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-23-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

R DEFUEL VALVE/WRG FAULT shows when the conditions that follow occur:

  • The Right Defuel Shut-off Valve is commanded to close
  • The open feedback-signal for the Right Defuel Shut-off Valve is true or the close feedback-signal is false

OR,

  • The Right Defuel Shut-off Valve is commanded to open
  • The open feedback-signal for the Right Defuel Shut-off Valve is false or the close feedback signal is true

Possible Causes:

  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • Right Defuel Shut-off Valve (L2)
  • Auxiliary Power Unit (APU) Start Contactor Assembly (ASCA) (A48)
  • Junction Box (JB6)
  • Junction Box (JB6)/PCB1
  • Auxiliary Power Unit (APU) Main Battery
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Junction Box JB6 AMM 24-00-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Junction Box JB6 AMM 24-00-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the APU Battery AMM 24-32-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the APU Battery AMM 24-32-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the APU Starter-Contactor Assembly AMM 24-62-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the APU Starter-Contactor Assembly AMM 24-62-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Defuel Shutoff Valves AMM 28-23-25-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Defuel Shutoff Valves AMM 28-23-25-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. The External (RDCP) LCD shows the Right refuel shutoff valve failed after doing the STOP/SOV test on the RDCP and access CAIMS:

    • Select System Diagnostics
    • Select 28-00 FUEL
    • Select Computer (FMQGC CH A)(B)
    • Select LRU TEST
    • Select RDCP and Refuel Valves Data
    • Review the RDCP panel status and the Refuel Solenoid Status

  2. Use the external RDCP and perform the SOV test for the RH Defuel Valve.
  3. Does the RH valve status change from CLOSED to OPEN or OPEN TO CLOSED on the PMAT.

    1. If the valve status changes, go to step 7.
    2. If the valve status stays OPEN, continue with the next step.

  4. Gain access to the Defuel shutoff valve (L3 and L2). Swap RH SOV L2 with LH SOV L3. Perform the SOV test from the RDCP.

    1. If the fault transfers to the opposite side, replace the RH SOV (L2) and do close out.
    2. If the fault does not transfer, continue with the next step.

  5. Swap the valves back to original positions. Remove connector L2P1 and perform a wiring check as follows:
    NOTE: Turn ON aircraft power for wiring checks.

    From To Expected Result Result
    L2P1-D Airframe Ground 28 VDC
    L2P1-E Airframe Ground Continuity
    L2P1-C Airframe Ground Continuity

    1. If the wiring at L2P1-C does not have a ground, repair or replace wiring to GS49 or GS49 and do close out.
    2. If the wiring at L2P1-E does not have a ground, repair or replace wiring to GS50 or GS50 and do close out.
    3. If wiring checks are good, go to step 7.
    4. If the wiring at L2P1-D does not have 28 VDC, continue with next step.

  6. Gain access to Junction Box 6. Open up the access cover to find test points. Perform a wiring check as follows:
    NOTE: The STOP/SOV switch would need to be depressed for wiring check.

    From To Expected Result Result
    PCB1-TP96 for A/C 9002-9119
    PCB1-TP93 for A/C 9120-9158
    Airframe Ground 28 VDC
    PCB1-TP26 Airframe Ground Continuity

    1. If the 28 VDC is missing on TP96 or TP93 and TP26 has a ground, suspect JB6 relay K1 in PCB1.
    2. If 28 VDC is missing on TP96 or TP93, suspect JB6.
    3. If the wiring check is good, go to step 8.
    4. If the ground is missing on TP26, continue with the next step.

  7. Remove FMQGC from the tray. Perform a wiring check as follows:

    From To Expected Result Result
    A47CP1-E5 JB6EP1-26 Continuity

    1. If the wiring check is not good, repair or replace wiring from FMQGC to JB6 and do close out.
    2. If the wiring check is good, continue with the next step.

  8. Re-install or re-rack the FMQGC making sure it is fully and properly pushed into place.
  9. Perform the SOV test on the RDCP, does the RH SOV fail.

    1. If NO, do close out.
    2. If YES, continue with the next step.

  10. Replace the FMQGC.
  11. Do close out.