07/17/19
Message Overview:
Fault Message:
CTR REFUEL/DEFUEL SOV SOLENOID/WRG
Fault Code:
2844640PK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-23-00 |
| Schematic Diagram: | 28-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-23-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
There is no power to the Center Refuel Valve from the Fuel Management Quantity and Gauging Computer (FMQGC).
Possible Causes:
- Junction Box (JB6)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB6 | AMM 24-00-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB6 | AMM 24-00-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Refuel/Defuel System | AMM 28-23-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the FMQGC and JB6. Perform a continuity check between the pins of the connectors that follows:
NOTE: Please note that Junction Box (JB) test points can be used to avoid removing the JB and the long return to service (See WM 28-23-00 sheet 3).From To Result JB6EP1-32 A47FP1-22 JB6EP1-33 A47CP1-A3 - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result JB6EP1-32 Ground JB6EP1-33 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Replace the junction box JB6.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Rerack the FMQGC making sure it is fully and properly inserted into place. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the FMQGC.
- Do close out.