Message Overview:
Message Code:
HS1R - HI LEVEL SENSOR/WRG
Message Code:
2844672PK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-41-00 - Fuel Management And Quantity Gauging System |
| Schematic Diagram: | 28-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-41-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
HS1R SENSOR, FUEL HI LVL/WRG FAULT shows when:
- HS1R High-Level Sensor or interface is out of range
- Sensor circuit is open
- Sensor circuit is shorted
- Sensor is contaminated OR,
- The Fuel Management and Quantity Gauging Computer (FMQGC) automatic calibration test failed (Circuit Fault)
Possible Causes:
- Right Wing Fuel Tank High Level Sensor HS1R (C2)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Standard Aircraft Configuration for Maintenance | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-801 |
| Aircraft Walkaround (for Maintenance) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-802 |
| Cleaning of the Fuel Management and Quantity Gauging System (FMQGS) Components | [ G5000 ] [ Global Express ] [ Global XRS ] AMM28-41-00-110-801 |
| Removal of the Computer | [ G5000 ] [ Global Express ] [ Global XRS ] AMM28-41-01-000-801 |
| Installation of the Computer | [ G5000 ] [ Global Express ] [ Global XRS ] AMM28-41-01-400-801 |
| Removal of the Wing-Tank High-Level Sensors | [ G5000 ] [ Global Express ] [ Global XRS ] AMM28-41-17-000-801 |
| Installation of the Wing-Tank High-Level Sensors | [ G5000 ] [ Global Express ] [ Global XRS ] AMM28-41-17-400-801 |
Troubleshooting Recommendations:
- On the CAIMS PMAT do the steps that follow:
- Select CAIMS.
- Select System Diagnostics.
- Select 28-00 Fuel.
- Select Computer (FMQGC CH A)(B).
- Select LRU TEST.
- Select RIGHT WING HIGH LEVEL DATA - CH A(B).
- Does HS1R (Inboard) sensor show a Circuit Fault?
- If NO, then go to step 9.
- If YES, then continue with the next step.
- Is there is a group of probes that are out of range?
- If NO, then go to step 9.
- If YES, then continue with the next step.
- Gain access under the number 2 RH wing fixed leading edge.
- Inspect the excitation feed wires RTP1 and RTP2. Move the wires around while someone else watches the PF capacitance values on the PMAT.
- Does the capacitance PF values move around drastically while moving shaking the wiring and connections on the PMAT?
- If YES, then repair the wiring or the connector and do close out.
- If NO, then continue with the next step.
- Disconnect RTP2, and perform a wiring check under the number 2 RH wing fixed leading edge as follows:
NOTE: Move the wire around to check for wire fractures or a bad connector.From To Expected Result Result RTP2 Center pin Ground 5 VAC ±0.5 RTP2 Center pin Shield Open - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Re-Connect RTP2.
- Re-rack the FMQGC. Access CAIMS active faults. Is the CAIMS message (2844672PK HS1R SENSOR FUEL HI LVL/WRG) still present?
- If the fault is not present, then do close out.
- If the fault is still present, then continue with the next step.
- Remove the FMQGC and disconnect RTP1. Perform a wiring check on RTP1 under the number 2 RH wing fixed leading edge as follows:
NOTE: Move the wire around to check for wire fractures or a bad connector.From To Expected Result Result RTP1-12 Ground Continuity RTP1-12 Shield Open - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Gain access to probe Right Wing High Level Sensor (C2).
- Visually inspect the sensor for contamination and condition.
- If the inspection results are not good, to to step 17.
- If the inspection results are good, continue with the next step.
- Gain access to connector RTJ1 inside the RH wing.
- Disconnect connectors RTJ2 and RTJ1. Inspect the connector for internal fuel or corrosion and general condition.
NOTE: Any black discoloring inside the connector should be cleaned and or replace the connector.- If the connectors are dirty, then clean the connectors per (AMM 28-41-00-110-801).
- If the connectors are good, then go to next step.
- Close access to the fuel tank and re-connect connectors RTJ2 and RTJ1, and re-install the FMQGC.
- Access CAIMS active faults. Is the CAIMS message (2844672PK HS1R SENSOR FUEL HI LVL/WRG) still present?
- If the fault is not present, then do close out.
- If the fault is still present, then continue with the next step.
- Replace the RH High Level Sensor (C2).
- If the fault is cleared, then do close out.
- If the fault is not cleared, then continue with the next step.
- Replace the FMQGC (A47).
- Do close out.